1. Measurement parameters : Z, L, C, DCR, ESR, D, Q, and q
2. Test conditions : 100Hz, 120Hz, 1KHz, 10KHz, 100KHz(MT4080a only), 1Vrms, 0.25Vrms, 0.05Vrms
3. 0.2% basic accuracy
4. Dual LCD display
5. Very quickly response
6. Fully auto/manual selection
7. DC resistance measurement
8. Rechargeable battery/ AC powered
9. User friendly
10. Infrared Interface ( RS 232C)

D Accuracy
D accuracy De is given as

Accuracy applies when Dx (measured D value) < 0.1
When DX > 0.1, multiply De by (1+Dx)

Q Accerarcy
Q accuracy is given as


Where, Qx is the measure Q value, De is the relative D accuracy
Accuracy applies when Qx · De < 1

q Accerarcy
q accuracy q is given as


Measuring Speed
Fast : 4.5 meas. /sec
Slow : 2.5 meas. /sec

General:
Temperature : 0°C to 40°C (Operating), ­20°C to 70°C (Storage)
Relative Humidity : Up to 85%
Battery Type : Ni­Mh or Alkaline (2AA size)
Battery Charge : Constant current 150 mA approximately
Battery Operation Life : 2.5 Hours typical
AC Operation : 110V/220V AC, 60/50Hz with proper Adapter
Low Power Warning : under 2.2V
Dimensions : 6.9" x 3.4" x 1.9" (LxWxH) (174mm x 86mm x 48mm) Weight : 470g

Order Information
MT4080A
100Hz to 100KHz Handheld LCR Merter
Standard Accessories
Shorting bar
DC 6V power adapter
AA-Size Ni-Mh rechargeable battery

Optional Test Fixtures/Accessories
TL08A SMD test probe
TL08B 4-wire test chips
TL08C 4-wire Kelvin chips
Carry case
RS232 To Infrared Adapter
产品功能描述  
频率范围 100Hz to 10KHz Handheld LCR Merter
精度范围 ±0.2%(MT4080D),±0.4%(MT4080A)
测试电平 1Vrms, 0.25Vrms, 0.05Vrms, 1Vdc(for DCR)
输出阻抗 100W, ±5%
显示参数  
Z 0.001Ω To 9999MΩ
L 0.001µH To 9999H
C 0.001PF To 9999F
DCR 0.000Ω To 9999MΩ
ESR 0.000Ω To 9999Ω
D 0.000 To 9999
Q 0.000 To 9999
q -180.0 To 180.0
测试速度 快速 4.5次/秒 慢速 2.5次/秒
温度 0℃-40℃(操作时) -20℃-70℃(储存时)
相对湿度 0-85%
连接方式 lrDA
传送信号 Tx及Rx
流程控制 XON/XOFF
电池  
电池寿命 2.5小时
产品特征  
长度 48mm
宽度 174mm
高度 86mm
重量 470g
产品持有证书  
  CE
其它功能  
  The MT4080A/MT4080D LCR Meter is the first handheld meter of this type on the Market, with a wide range of test frequencies up to 10KHz (MT4080D) or 100KHz (MT4080A), and many measurement parameters including Z, L, C,DCR, ESR, D, Q, and q as well. The MT4080A/MT4080D is design for both component evaluation on the production line and fundamental impedance testing for bench-top applications. With a build-in direct test fixture you can test the lead components very easily. The 4-wire test clip can give a convenient connection to larger components and assemblies ith the accuracy of 4-wire testing. The LCR meter offers fast,reliable,and versatile testing at low cost.Furthermore, the optional RS232C interface (IrDA) is an attractive, cost-effective solution for quality assurance and incoming inspection operations,making the MT4080A/MT4080D is the most advanced handheld LCR meter available on the market today.

ESR measurement
In today's switching mode power supply design, higher frequency is reached everyday to take advantage of the size and output power barrier. To ensure the performance of the circuit, the Equivalent Serial Resistance (ESR) in a capacitor is the key element determining efficiency and performance. With mt4080a/Mt4080D the user can quickly check the ESR of a capacitor up to 100KHz or 10KHz without hesitation.

Built-in infrared Port
MT4080A/MT4080D comes with a bulit-in infrared port to allow communication with a personal computer.With the fully Remote Control Command (RCC) support,both units are able to act as an automatic LCR testing system-this is especially applicable in automatic Q.A and I.Q.C testing. The user is able to control the measurements and get the measured values through the IrDA port.Remote-Binning feature,easily sorting the components ,is combined with remote-binning software and infrared port.

SMD test probe(optional)
Surface_mount components are usually tiny and have no wire leads, making it more difficult to test surface_mount devices than conventional components. The TL08 SMD test probe gives users an easy way to conduct SMD component testing.The uniquely designed SMD test probe can also be used to test conventional components if the wire leads are too short to insert into the test terminals.

Open and short calibration
In the world of LCR meters,open and short calibrations are important procedures before making any measurements, especially when user changes the testing frequency and level. Therefore, very fast open and short calibrations are the key factors to the user. Within just 10 seconds, the user can perform open or short calibrations at any frequency and level that s/he desires.

Transfromer measurement
To qualify xDSL transformers, you can measure the primary inductance or coupling capacitance at 10KHz,and leakate inductance at 100KHz with lower test voltage. You can also measure the DC-resistance of primary and secondary with the standard DCR function.